Keep the positions with the measurements.
Record a catch-can grid, inspect the lowest quarter and compare a later test without separating the readings from their setup.
Catchgrid is an informal sprinkler-measurement worksheet for iPhone and iPad. Start with an empty test or import your complete CSV. A missing reading stays different from a measured zero.
An upfront purchase includes all current tools. No subscription or in-app purchase. No account or app backend.

See exactly which positions make the lowest quarter.
Analysis lists the lowest count ÷ 4 readings and shows their mean alongside the all-position mean. Ties use row, then column order.
DU = lowest-quarter mean ÷ overall mean × 100. The measured rate uses your entered duration. A target-time estimate assumes that average rate stays constant.
All-zero readings have undefined DU and target time. Smaller grids remain informal worksheets; these results do not certify a professional audit or prescribe a controller schedule.

Record where the cans and heads were placed.
Add a fixed reference, row and column directions, metres or feet, spacing and offsets. Optional head markers keep your manually entered locations with the test.
The schematic and exact position table use the distances you enter. They are not GPS locations, surveyed coordinates or detected equipment. Export the recorded can and head positions as CSV.
Markers can overlap in the schematic; use the exact position table to inspect distances.

Retest against the recorded setup.
Start a blank retest from a complete measurement. It links the baseline and copies its placement snapshot. Enter new measured depths and the actual new duration; record conditions and setup labels for that observation.
Each position’s rate uses its own test duration. DU change is shown in percentage points. Different recorded placement snapshots withhold paired changes. If a plan is missing, pairing uses grid IDs only and physical correspondence stays unknown. Matching snapshots or labels cannot verify field conditions, establish a cause or demonstrate water savings.
Export the readings, originals and a restorable backup.
Native sharing can deliver current CSV, a readable report, a JSON backup and an integrity manifest, plus placement, original-source and baseline/comparison files when present. The file count depends on the evidence available in that test. Imported source bytes stay separate from current edits; a manual test does not acquire an invented original CSV.
Import a valid JSON backup to create independent copies of its test and included baseline. A partial draft can be backed up too. Keep important backups outside the app before deleting data or uninstalling. SHA-256 checks bytes, not the truth of a field observation.
Know the limits before measuring.
Use equal containers, suitable sampling and repeatable physical positions. Catchgrid does not operate valves, connect to sensors or controllers, measure pressure or weather, prescribe repairs, or guarantee water savings.
Read input limits, recovery and export instructions · How local data and sharing work