Support
Contact maga40@naver.com with Paneveil, your app/iOS version and the action that failed. Share a redacted screenshot or sample only if you choose.
Start with your own readings
Surveys → New survey → Add window. Enter air temperature, relative humidity and glass temperature, then Save reading. Use New reading for another visit and Edit reading to correct an existing record. Unsaved values are labeled. No login or sensor connection is required.
Compare two visits
Open a window’s History. Choose a baseline and follow-up reading. Share this comparison CSV exports that exact pair, including their IDs, times and source record numbers. Displayed contributions are rounded separately; CSV retains full calculation precision. The breakdown averages all six orders of changing the three inputs and explains the calculation, not physical causes.
Compare at a chosen time
Compare → choose a target time and a tolerance from 0–120 minutes. Each window uses the closest saved reading within the interval; equal-distance ties use the earlier time. Excluded windows remain visible. Input ranges default to zero. Enter your own air/glass bounds up to ±5°C and humidity bounds up to ±20 percentage points. All bounds must stay in the supported measurement domain; invalid ranges produce no band and are not clipped. No interpolation or automatic monitoring.
Import CSV
Surveys → Share CSV template, or Import CSV → Files. UTF-8 CSV up to 4 MiB and 2,400 data records. Required headers: Window, Timestamp UTC, Air C, RH percent, Glass C. Optional: Room, Buffer C (default 2), Moisture observation, Note. Extra computed columns are ignored. ISO 8601 timestamps need a timezone; quoted commas, quotes and newlines are supported.
Review accepted records and skipped reasons before Import accepted readings. Duplicate window/room/timestamps keep the first valid record. Structural errors stop the import. Original bytes and record numbers stay separate from later current edits or deletions. Manually entered records do not acquire an invented source file.
Share and restore
Report → Preview PDF or share readings, PDF, backup or measurement files. The measurement bundle includes current/matched/corner CSV, PDF, JSON and a hash manifest; imported surveys also include original CSV and a source-record audit. Surveys → Restore survey backup accepts a valid backup up to 12 MiB and creates separate IDs. Invalid backups preserve saved surveys. Save backups outside the app before uninstalling. Deleting a record does not delete previously shared files.
Supported limits
Air/glass 0–45°C equivalent, humidity 5–100%, chosen buffer 0–5°C. Up to 24 surveys, 24 windows per survey, 100 readings per window, 80 characters per name and 1,000 per note. Workspace 128 MiB. PDF history includes up to 250 readings; CSV and JSON retain every saved reading. PDF uses selected units/local time; CSV keeps Celsius, UTC and epoch timestamps. Unreadable local storage is preserved and blocked from overwriting.
Understand the result
Surface margin is measured glass minus approximate water dew point. It is a calculated temperature relationship, not observed droplets, a building defect or a humidity recommendation. Moisture observation is a separate input. The curve keeps air/glass values fixed. There is no frost, mold or health/safety diagnosis. System file providers and device backups follow your settings.